Quicklub QLS 401 Electric Grease Pump - Remote Control
Lincoln Quicklub QLS 401 Electric Grease Pump - Remote Control The QLS 401 for Remote Control allows customers to be in control of the lubrication process. The 24 VDC models monitor system cycling with a proximity switch. An external timer or PLC controls the interval between lube cycles. The 120 VAC models have no cycle monitoring and are on/off controlled by the user's external timer or PLC. The minimum pause time requirements should be followed when setting up the external controller. (Optional low-level control). Model No. P40191401110 Operating Voltage - 24 VDC- 120 VAC- 50/60 Hz Operating Current - 24 VDC/1.0 A- 120 VAC/1.0 A Operating Temperature -10°F to 158°F/-25°C to 70°C Number of Outlets 6, 8, 12 or 18 Reservoir Capacity 61"/1.0 L Protection NEMA 4 Minimum Pause Time 4 min. DC models/20 min. AC models Maximum Operating Time 25 min. DC models/15 min. AC models Timer Memory Indefinite Maximum Operating Pressure 3000 psi/205 bar Out